Test Code UREDF Reducing Substance, Feces
Reporting Name
Reducing Substance, FUseful For
Assisting in the differentiation between osmotic and nonosmotic diarrhea
Screening test for:
-Diarrhea from disaccharidase deficiencies, (eg, lactase deficiency)
-Monosaccharide malabsorption
Specimen Type
FecalSpecimen Required
Supplies: Stool container, Small (Random), 4 oz Random (T288)
Container/Tube: Fecal container
Specimen Volume: 3 g
Collection Instructions:
1. Collect a loose, unpreserved, random fecal specimen.
2. Freeze immediately.
Additional Information: If additional tests are ordered, aliquot and separate sample prior to freezing to allow 1 container per test.
Specimen Minimum Volume
2 g
Specimen Stability Information
| Specimen Type | Temperature | Time |
|---|---|---|
| Fecal | Frozen | 7 days |
Reject Due To
| Urine and feces mixed Feces collected in any preservative or fixative |
Reject |
Reference Values
Negative or trace
Day(s) Performed
Monday through Saturday
Performing Laboratory
Mayo Clinic Laboratories in Rochester
Test Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
84376
LOINC Code Information
| Test ID | Test Order Name | Order LOINC Value |
|---|---|---|
| UREDF | Reducing Substance, F | 11060-1 |
| Result ID | Test Result Name | Result LOINC Value |
|---|---|---|
| 6215 | Reducing Substance, F | 11060-1 |
Method Name
Benedict's Copper Reduction Reaction
Forms